Any potential user should ensure, in consultation with the manufacturer, that the CWMS is suitable for the process on which it will be installed. It is important to refer to the details on certificates issued as they may contain specific limitations on use. The certificate holders listed have submitted satisfactory test reports and successfully undergone a product manufacturing audit. For instruments used under ‘Minimum Requirements for the Self-Monitoring of Flow’ scheme, the total daily volume of the discharge specified in the permit shall be measured with a target uncertainty of ±8%. The MCERTS inspector will determine whether the specific onsite calibration and set up meets the minimum requirements of the Self Monitoring of Flow MCERTS standard.
Issue 102 Updated 19/07/2019
Certificate holderModelCertified rangeCertificate No.

ABB Ltd

Tel: +44 (0)1453 826661

www.abb.com

Watermaster V Electromagnetic flow meter with WaterMaster Transmitter
&
Watermaster F Electromagnetic flowmeter with WaterMaster Transmitter
&
Watermaster W Electromagnetic flowmeter with WaterMaster Transmitter

Watermaster V:
DN40 to DN200
(excluding DN60 & DN125)

Watermaster F:
DN250 to DN2200

Watermaster
WDN10 to DN2400

See certificate for
certified flow ranges

Version issued:
09/10/2018

Class 1

Detectronic Ltd

Tel:+44 (0)1282 449124
[email protected]

www.detectronic.org

Detectronic UDFMFC
Dual

0 to 1.5 metres (nominal)

Version issued:
12/02/2015

Class 1

Detectronic Ltd

Tel:+44 (0)1282 449124
[email protected]

www.detectronic.org

Detectronic UDFMFC
Lite and remote
temperature sensor

0 to 3 metres (nominal)

Version issued:
12/02/2015

Class 1

Detectronic Ltd

Tel:+44 (0)1282 449124
[email protected]

www.detectronic.org

MSFM S2U Multi
Sensor Flow Monitor

0to 30l/s for 197mm channel
0 to 20l/s for 152mm pipe
0 to 25l/s for 188mm pipe
O to 30l/s for 244mm pipe

Version issued:
16/08/2018

Class 3

Dynamic Flow Technologies Ltd

Tel: +44(0)115 871 8565

www.dynamicflowtech.com

Waste Water Meter
Assembly 100
(WWMA100)

0.05 to 5.150 l/s

Version issued:
07/06/2018

Class 3

Flexim Industriemesstechnik GmbH

Tel: +44 (0) 1606781420

[email protected]

www.flexim.co.uk

FLUXUS F721
Ultrasonic Flowmeter

Velocity 0.25m/s to 5m/s
Pipe diameter 0.1m to 1.2m

Version issued:
11/04/2018

Class 1

GE Sensing EMEA

Tel: +353 61 470200
www.gesensing.com

GE Sensing (UK agent)
Tel: +44 (0)116 231 7100

Panametrics DF868
Ultrasonic Liquid
Flowmeter

0.25 to 5m/s

Version issued:
23/10/2018

Class 1

KROHNE Altometer

Tel:+44 1933 408500
[email protected]

www.krohne.co.uk

WATERFLUX 3070

Electromagnetic
flow meter and signal
converter

DN25 to DN300

See certificate for certified
flow ranges

Version issued:
08/11/2015

Class 1

KROHNE Altometer

Tel:+44 1933 408500
[email protected]

www.krohne.co.uk

WATERFLUX 3100

Electromagnetic
flow meter and signal
converter

DN25 to DN500

See certificate for certified
flow ranges

Version issued:
17/11/2017

Class 1

KROHNE Altometer

Tel:+44 1933 408500
[email protected]

www.krohne.co.uk

WATERFLUX 3300

Electromagnetic
flow meter and signal
converter

DN25 to DN500

See certificate for certified
flow ranges

Version issued:
17/11/2017

Class 1

KROHNE Altometer

Tel:+44 1933 408500
[email protected]

www.krohne.co.uk

OPTIFLUX 2100

Electromagnetic
flow meter and signal
converter

DN25 to DN500

See certificate for certified
flow ranges

Version issued:
28/02/2018

Class 1

KROHNE Altometer

Tel:+44 1933 408500
[email protected]

www.krohne.co.uk

OPTIFLUX 2300

Electromagnetic
flow meter and signal
converter

DN25 to DN500

See certificate for certified
flow ranges

Version issued:
28/02/2018

Class 1

MJK Automation ApS

Tel: (+45)45560656

www.mjk.com

MJK MagFlux 7200

Velocity
Pipe size
0.1m/s to 10 m/s
25mm to 400mm

Version issued:
01/11/2016

Class 2

MJK Automation ApS

Tel: (+45)45560656

www.mjk.com

Flygt MagFlux EMF
801

Velocity
Pipe size
0.1m/s to 10 m/s
25mm to 400mm

Version issued:
16/12/2016

Class 2

Nivus GmbH

www.nivus.com

NivuFlow750
(incorporating POA-K sensor)
Echo Profile Flowmeter

Velocity
Depth
0.1to 2.5m/s
0.075 to 0.8m

Version issued:
21/07/2016

Class 2

Nivus GmbH

www.nivus.com

NivuFlow 750
Echo Profile Flowmeter
and POA-R sensor

Full Pipe Applications

Velocity 0.1 m/s to 3 m/s

Pipe size DN150, DN300
and DN500

Version issued:
14/04/2017

Class 2

Nivus GmbH

www.nivus.com

NivuFlow750
Echo Profile Flowmeter
with POA-R sensor
and i-Sensor

Partially Filled Pipe
Applications

Velocity 0.1 m/s to 3 m/s

Fluid depth 0.075m to 0.8m

Version issued:
14/02/2017

Class 3

Nivus GmbH

www.nivus.com

NivuFlow 550
with Velocity Radar Sensor
and air ultrasonic
level i-Sensor

Velocity 0.15 to 2.5m/s

Depth 0.05m to 1.6m

Version issued:
11/04/2019

Class 3

Pulsar Process
Measurement Ltd

Tel:+44 (0) 1684 891371

www.pulsar-pm.com

FlowCERT with DUET transducer

0 to 1.5 metres (nominal)

Version issued:
07/11/2018

Class 1

Pulsar Process
Measurement Ltd

Tel:+44 (0) 1684 891371

www.pulsar-pm.com

FlowCERT Lite with
dB3 transducer and
remote temperature
sensor or dB3 with
twin Pulsar sun
shields using
internal temperature
compensation

0 to 3 metres (nominal)

Version issued:
07/11/2018

Class 1

Pulsar Process
Measurement Ltd

Tel:+44 (0) 1684 891371

www.pulsar-pm.com

Flow Star with dB3
transducer and remote
temperature sensor or
dB3 with twin Pulsar
sun shields using
internal temperature
compensation.

0 to 3 metres (nominal)

Version issued:
07/11/2018

Class 1

Rosemount Measurement Ltd

Tel: +44 (0)1753 756600

www.mobrey.com

MSP900FH-A (or Rosemount 3108)
Level Transmitter &
MCU900 (or Rosemount 3490)
Series Transmitter
Control Unit

0 to 3 metres (nominal)

Version issued:
02/11/2018

Class 1

Siemens AG

www.siemens.com/flow

SITRANS FM MAG
3100Electromagnetic
lowmeter

DN15 to DN2000

See certificate for
certified flow ranges

Version issued:
02/11/2018

Class 1

Siemens AG

www.siemens.com/flow

SITRANS FM MAG
5100W Electromagnetic
flowmeter

DN25 to DN1200

See certificate for
certified flow ranges

Version issued:
02/11/2018

Class 1

Siemens AG

www.siemens.com/flow

SITRANS FM MAG
8000 & MAG8000
CT Battery Powered
Electromagnetic flowmeter

DN25 to DN600
See certificate for
certified flow ranges

Version issued:
02/11/2018

Class 1

Siemens AG

www.siemens.com/flow

SITRANS Probe
& LU240 HART

0 to 2.75m

Version issued:
19/07/2019

Class 2

Siemens Canada Ltd

Tel: +44 (0)8458 507600

www.siemens.com/hydroranger

HydroRanger 200
Controller with
Echomax XRS-5
ultrasonic transducer

0 to 2 metres (nominal)

Version issued:
23/09/2015

Class 2

Siemens Canada Ltd

Tel: +44 (0)8458 507600

www.siemens.com/LUT400

SITRANS LUT430
Ultrasonic Level
Instrument

0 to 3 metres (nominal)

Version issued:
04/07/2018

Class 2

Siemens Canada Ltd

Tel: +44 (0)8458 507600

www.siemens.com/LUT400

SITRANS LUT440
Ultrasonic Level
Instrument

0 to 3 metres (nominal)

Version issued:
04/07/2018

Class 1

Siemens Industry, Inc.

Industry Automation Division –Process Instrumentation and Analytics

Tel: +44 (0)8458 507600

www.siemens.com/fs220

SITRANS FS220
Ultrasonic Clamp-on
Flowmeter

0.25 m/s to 6 m/s

Version issued:
29/03/2019

Class 1

Siemens Industry, Inc.

Industry Automation Division –Process Instrumentation and Analytics

Tel: +44 (0)8458 507600

http://www.siemens.com/fs230

SITRANS FS230
Ultrasonic Clamp-on
Flowmeter

0.25 m/s to 6 m/s

Version issued:
29/03/2019

Class 1

Teledyne ISCO Inc.

Tel: +1 (402) 464 0231
[email protected]
www.isco.com

UK Sales: RS Hydro
Tel: +44(0)1527 882060
Fax: +44(0)1527 558999
Email: [email protected]
Website: www.rshydro.co.uk

Signature® Flowmeter with TIENet™ 360 LaserFlow Velocity Sensor

Velocity
Depth
±0.25 to ±1.7 m/s
0.01 to 0.75m

Version issued:
04/11/2014
Class 2

Teledyne ISCO Inc.

Tel: +1 (402) 464 0231
[email protected]
www.isco.com

UK Sales: RS Hydro
Tel: +44(0)1527 882060
Fax: +44(0)1527 558999
Email: [email protected]
Website: www.rshydro.co.uk

Signature® Flowmeter with 350 Velocity Sensor

Velocity
Depth
0.15 to 2 m/s
0.1 to 1m

Version issued:
09/04/2019
Class 4

Teledyne ISCOInc.

Tel: +1 (402) 464 0231

[email protected]
www.isco.com

UK Sales: RS Hydro
Tel: +44(0)1527 882060
Fax: +44(0)1527 558999

Email: [email protected]
Website: www.rshydro.co.uk

Signature®
Flowmeter with
TIENet™ 330 Bubbler
Module

0.003 to 3m

Version issued:
11/08/2014

Class 2

Teledyne ISCOInc.

Tel: +1 (402) 464 0231

[email protected]
www.isco.com

UK Sales: RS Hydro
Tel: +44(0)1527 882060
Fax: +44(0)1527 558999

Email: [email protected]
Website: www.rshydro.co.uk

Signature®
Flowmeter with
TIENet™ 310
ultrasonic level sensor

0.003 to 3m

Version issued:
04/11/2014

Class 3

VEGA Grieshaber KG

Tel.: +44(0)1444 870055
Email: [email protected]
Website: www.vega.com/uk

EGAPULS WL61 radar level sensor with VEGAMET 391 flow computer
VEGAPULS 61B radar level sensor with VEGAMET 391 flow computer

Depth 0 to 5m

Version issued:
31/10/2018
Class 2